14 of 1934 - Amending the third paragraph and subsection (B) of Section 507, Revised Ordinances of 1934, relating l:ee.1118
ROLL CALL
VOTING AYE NAY f �� Salt Lake City,Utah, June 7 193 4
GogginTI I move that the ordinance be d.
Keyser
Knight1Z7)7
Lee V
AIL Chairman - -
A ORDINANCE
Result
AN ORDINANCE AMENDING the third paragraph and sub-
section (b) of Section 507 of the Revised Ordinances of Salt
Lake City, Utah, 1934, relating to location, construction and
installation of underground tanks.
Be it ordained by the Board of Commissioners of Salt
Lake City, Utah:
SECTION I. That the third paragraph of Section 507
of the Revised Ordinances of Salt Lake City, Utah, 1934, relat-
ing to the location, construction and installation of underground
tanks be and the same is hereby amended to read as follows:
No underground tank. within the limits of Fire
Zone No. 1 shall have a capacity of more than 1,000 gallons
and not more than a total of 4,000 gallons shall be stored
on any one parcel of land. No underground tank outside of
the limits of Fire Zone No. I shall have a capacity of more
than 7,000 gallons and not more than a total of 14,000 gal-
ve
lons shall be stored on any one parcel of land. In the event
more than one such tank is installed, then each tank shall be
separated from the others by at least two (2) feet of sand
forty (40
and no tank shall be closer than the x fact from any
over one (1) story in height,
adjoining building,/the actual service station structure
being excepted.
SECTION 2. That sub-paragraph (b) of said Section 507 of the
Revised Ordinances of Salt Lake City, Utah, 1934, relating to the
location, construction. and installation of underground tanks be and
the same is hereby amended to read as follows:
(b) CONSTRUCTION. With the exception of existing under-
ground tanks in good condition, all tanks shall be made of
14
it
-a-
�ii
galvanized steel, basic open hearth steel, or wrought iron
of the following U. S. Standard gauge or thickness depending
upon the capacity, to-vvit:
Capacity--gallons. Minimum thickness of material.
1 to 560 14 U. S. Standard gauge
561 tt5 1100
12 U. S standard gauge
1101 to 4000 7 U. S. Standard gauge
11
4001 to 7000 one-quarter inch
SECTION 3. In the opinion of the Board of Oommissi.oners,
it is necessary to the peace, health and safety of the'inhabitants
of Salt Lake City that this ordinance shalltake effect immediately'.
SECTION 4. This ordinance shall take effect at once upon
ipublication. •
p
/ ` ://
• Passed by the Boar o Commissioners of Salt Lake City,
June
Utah, this 7th day of , ls.D. 1934.
Mayor.
r/I 1 � g,
�•�9 rL 9`ryzfitf�
City ecorder.
ii
,,4
. .
1
. . _ . • • .
, .
. . 1
. . .
. '
....
\ 1 2
fial � ' � t j- a
0
z ` ID v :. a o
•, ...; J
``\ Y ,� .
+ CI
� WM
*.4.
.
Affidavit of Publication
STATE OF UTAH,�
County of Salt Lake
`. AN ORDINANCE -
I'`N O30U1NANC1 AMENDING the Leo ;�� Young
igll'a.;y¢,'a6raYh"+nd'dv becctloa (h) ol', U
tib to oY ty. t h,'1 Ul'd elatioal
04 Sala ion,construction
tilty, Utah,'ond in relation
p of.underground
coda rn tlsn Installation
!r•e It ordained ibex!. Beingfirst dulysworn,deposes and says that he is the advertis-
,tnIssionera dof n Salt Lake the City. Utah: Y
puotion I. That the tl,lr,l paragraph
Oft Section e07 or the Revised Ordinances in clerk ofTHE DESERET NEWS,a newspaper published in
,at:.ealt Lake City."WAR 1034, relatling. newspaper
ore'lecation, construction and.�;t4llatlou [ de.grouue,}Canks be ad
i.nerdby a sea to read e Salt Lake City,Salt Lake County,in the State of Utah.
,�01�lo;va:`.
tdergronnd tank wltl,in the lhn-I
;p$itf elucia than 140001gallone a and
.,hdt y oftiait a total of 4,000 gallons That the advertisement Ordinance- Salt---L-ske
more one °areal or
',a Wµ,al N underground
on any outsidav et
-1the-limits
un f trirund teak
",tax Ilnrits of irlre Zone No, 1 :halt ,
bare a capacity lore than 7,000 C.it,y__13.1,11..i?.o.."..14_.r-el;_tin _.tn.-node.r-,�r=o-uni
of
tutu 00th of]arid11 In tlle1 ed f pry
I tt,tnponoe uch tank is installed, than tanks -
.each tank'shall be separated from the
'egrets by at least two (3) feet of sand
and no tank shalt bo closer that forty
{44) feet from any adiolning building.
Over 0 _tl) story In height, the s
,tual s evlee station structure being ex-
,e4tetl.
seeuon a. That sub-paragraph (b) of was published in said newspaper, in its issue 'dated, the
I(@ t�d Section 507 f the. Or-pancee'of Salt Lake Clty,]itch.1934,
Ise al hl8'to the iodation, construction
4 )� A
la4d Inetaliatlon.of underground tanks 8t:1 day of June A.D.19-_-34
•4 pfl and the tamale'hdratiy amended
.to.read as tRUd'A
n 0 N fisting noanrON.With thanke sD-
of condition,
underground tank! In
.11ryrt made and was published.__.one..-isauE
good ondltlon, 11 tanks!hall'b0
't:g)ro nlxod heel, basic open hearth
'IT` ,'a'Standard
iron of the toes de-
4Te S.'Standard gangs r thickness do •
-
eltding goon the aaDacity,to-wit: the last publication thereof being in the issue;dated the
'1 bitnof Material,thickness
tie 1 to—Mellon! of ndga
-1 t0 100- 14 U.S.standard gange day o f A.D. 19
'S81-to 1000 12 U.S.Standard gauge
:1101 to 4'000 '7-U.n a ey tnnie gauge
s Fa to 703. one-opinion ofth �
Faction 0.Commissioners,
the opinion necessary
L the to arft
''pekoe.
health
and it a ne eery to the:
',aitts• health and safety f the is oath-,
jnane of Salt Lake any of this rfti-' Advertising erk.
eh'1. This
erred Lce shall to
'n tectlot 4. This-ordinance hall take
�le[gact�at once anon publication.
66 J'a d b.v ote Board or cth a 0nlonern,
Of June, A,
30, y934,tah, Chia 7th day
tt ,,.I0outt MARCIlyor.
T1LIDI.MACDONALD, '
7
Subscribed and sworn to before me this 12t11 day of
J une A.D. 19 34
y>i- -1 fl i•„ .,,
N,,ar 'P blic.
c
o
1.4•
•mo.
r' •