Result AN ORDINANCE
•''/,
AN ORDINANCE AMENDING CHAPTER 9 OF TITLE 49 of the Revised Ordi-
nances of Salt Lake City, Utah, 1965, relating to fire hydrants for
private purposes.
Be it ordained by the Board of Commissioners of Salt Lake City,
Utah:
SECTION 1. That Chapter 9 of Title 49 of the Revised Ordinances
of Salt Lake City, Utah, 1965, relating to fire hydrants, be, and the
same hereby is, amended to read as follows:
CHAPTER 9
FIRE HYDRANTS FOR
PRIVATE PURPOSES
Sections:
49-9-1. Fire hydrants for private purposes.
49-9-2. Fire hydrant specifications.
49-9-3. Water main requirements.
49-9-4. Number of hydrants required for a building.
49-9-5. Bond.
Sec. 49-9-1. Fire hydrants for private purposes. (a) No con-
nections to and/or the installation of water lines or mains involv-
ing one or more fire hydrants for private fire protection purposes
shall be made without issuance of a special permit from the Board
of Commissioners of Salt Lake City.
(b) Any installation of a fire hydrant on private property shall
be made at the sole expense of the person requesting such an install-
ation and shall be perpetually maintained by said applicant.
(c) Installation made on public property for private purposes
shall be made at the sole expense of the person making application
therefor and shall be installed in accordance with city ordinances
and perpetually maintained by the applicant.
(d) If at any time an applicant shall fail to comply with any of
the foregoing requirements, the General.Superintendent of the Salt
Lake City Water Department may, after ten (10) days written notice
to applicant and failure to comply therewith, terminate service to
the fire hydrant and/or remove it entirely.
(e) In no event shall any building erected on private property
and used as a dwelling unit for more than four individual family
dwelling units, or for any purpose other than as a dwelling, be loc-
ated more than two hundred (200) feet from a fire hydrant, measured
along the curb in front of each said fire hydrant. All water outlets
on said fire hydrants installed hereunder must, as nearly as possible,
face the nearest access or dedicated street.
Sec. 49-9-2. Fire hydrant specifications. All hydrants installed
hereunder must comply with the then current specifications for fire
hydrants of the Department of Water Supply and Waterworks.
Sec. 49-9-3. Water main requirements. No new water main install-
ation used to service a fire hydrant system shall be smaller than
six (6) inches in diameter. 144
-2-
Sec. 49-q-4. Number of hydrants required for a building. The
following table shall be used in determining the number of hydrants
to be used for fire protection in connection with the construction of
any building not excluded hereunder, with the location of each such
hydrant to be determined and designated by the Chief of the Salt
Lake City Fire Department:
BUILDING AREA SQUARE FEET NUMBER OF HYDRANTS REQUIRED
1 Story 2 Stories or more
(without basement) (1 story and basement)
Up to 5,000 1 1
5,000 to 15,000 2 2
15,000 to 40,000 2 3
40,000 to 100,000 3 4
100,000 to 200,000 4 5
200,000 to 300,000 5 6
300,000 to 400,000 6 8
Over 400,000 Discretion of the Fire Department
Sec. 49.9-5. Bond. A performance bond in an amount adequate to cover the
cost of construction must be posted before any installation of fire
hydrants can begin hereunder in order to assure compliance with the
foregoing. Said bond will not be released until the requirements
hereof are met and all water mains and fire hydrants connected thereto
are certified in writing to be in good operating condition by said
General Superintendent of the Department of Water Supply and Waterworks.
SECTION 2. In the opinion of the Board of Commissioners it is neces-
sary to the peace, health, safety and welfare of the inhabitants of Salt
Lake City that this ordinance become effective immediately.
SECTION 3. This ordinance shall take effect upon its first publi-
cation.
Passed by the Board of Commissioners of Salt Lake City, Utah, this
14th day of December, 1972.
YOR
�/. kMA .
ITY REI'A.
(SEAL)
BILL NO. 144 of 1972
Published December 19, 1972
[44
Affidavit of Publication
STATE OF UTAI-I,
ss.
County of Salt Lake
.
AN ORDINANCE
AN ORDINANCE AMENDING CHAPTER 9 OF TITLE 49 of the Revised Betty
Ordinances of Salt Lake City,Utoh,.1965,relating to fire hydrants for private ._�-�( -_(_h_(%-�-l�;
purposes.
r
Bo it ordained by the Board of Commissioners of Salt Lake City,Utah:
SECTION 1.That Chapter 9 of Title.49.af the Revised.Ordinances of Salt r
Lake City,Ufah,1965,relating to tirelhydrants,.be;and the same hereby is,
amended t read as follows: Being first duly sworn,deposes and says that he is legal adver-
CHAPTER9 ". DESERET C�i�RT.�Y�NEWS, Sunday)
FIRE HYDRANTS FOR �itisl.ng clerk of the DESEtit'll IYl'�]'V S, a daily except
Sections: PRIVATE PURPOSES
49tion. Fire hydrants for private purposes. 'newspaper printed in the English language, with general cn'-
1 n9-9-2.3. Fl hydrants
specifications.
•culation in Utah, and published in Salt hake City, Salt Lake
• 49-9-4. Number of hydrants required for a building. • ;County, in the State of Utah.
49-9-5. Bond. y
Sec.49-9-1.Fire hydrants far private purposes.(a).No connections to ,!�nd/-or the installation of water lines or mains Involving one or more fire That the legal notice o f which a copy is attached hereto
' eta for erivatd fire protection purposes shall be made without issuance
of a special permit from the Board of Commissioners of Salt Lake City.
(b) Any installation of a fife hydrant on private property shall be made 1 the solo expense of the person requesting such an installation and shall be I /I ti Or0.1_L1a,Y1oo re la C I r.)(' to fir() 1,2xcira.n CS .-Far -or-i.va.ta
Uerpetualiy maintained by said applicant.
(c)Installation made on public property for private purposes shall be
de of the sole expense of the person making application therefor and shall )
be-installed In accordance with city ordinances and perpetually maintained I)llrl)(l SO.9 e j I�.1- WO e 144 oi` L(())/`j2 e
by the applicant. _
I11I 10 If at any time on applicant shall fail to comply with any of the forego-
ing requirements,the General Superintendent of the Salt Lake City Water De-
ccomplynt therewith,after
terminate service written
thee Hire hydrrance to tcant andand remote to
remove entliely.
(e)in no event shall any building erected on private property and used os i
'a dwelling unit for more than tour Individual family dwelling units,or for any '
purpose other than as a dwelling.,be located more than two hundred 1200)feet -
'from a fire hydrant,measured along the curb In front of each said tire
1.hydrant.All water outlets on said fire hydrants installed hereunder must,as
nearly as possible,face the nearest access or dedicated street.
Sec.d9-94.Fire hydrant specifications.All hydrants installed hereunder _.
must comply ater the then Supple current
renteswspecifications for fire hydrants of the De-
qar
Sb.4998.WateoL�ppo ',Irement .N no w ater main Installation
hmedtt service a fire hytl and system shall b aler than six(61 Inches In el- .was published in said newspaper on
Sec.49-9-4.Number of hydrants required for a building.The following
"table shall be used in deeelmining the number of hydrants to be used tot fire O
Tateaion in connection with the construction of any building not excluded I)0C0t b>✓T`_]9 _19Jr„
•hereunder,with the Station of each such hydrant to be determined and desi9- ---""'
hated by the Chief of the Salt Lake City Fire Department:
BUILDING AREA SQUARE FEET
NUMBER OF HYDRANTS REQUIRED ----— -- -'—'- \ ,s
1 Story 2 Stories or more 1
(without basement) (1 story and bosement) )
:Up to 5,000 1 I _`-Ai�V S��r�:��
s,ggprots,poo 2 z -------- �
e in
is,apo to 4a,aoo 2 B Legal/1(V rttsingrr(.1Zerk
'40,000 to 100,000 B 4 6 is
100,000 to 200,000 4 5
200,000 to 400,000 5 6 •
]W,000 to 400,000 6 8 '
Over 400,000 Discretion of the Fire Department
Sec.49-9-5.Bond.A performance bond in an amount adequate to cover the
cost of construction must be posted before any Installation of fire hydrants
i can bond wain ill notreunder In order to assure be released until the requirements ahereof nce faro met and oil watee foregoing. r 2 1,b - ------ day of
me this 0
mains and ironire hydraconditiosn
y sold tl thereto Su are cSuperintendent
In p0 to
good Operating condition by said General SupeNntentlent of the Department Of
Water Supply and Waterworks. A.D. In——/,-•
SECTION 2.In the opinion of the Board of Commissioners It Is necessary 1, l L
to the peace,health,safety and welfare of the Inhabitants of Solt Lake City
',.that this ordinance become effective Immediately,
SECTION B.This ordinance shall take effect upon its first publication.
Passed by the Board of Commissioners of Salt Lake City,Utah,this 14th
day of December,1972.
.. E,J.GARN --
Mayor -- �(�•,./, /. ��.
HERMAN J.HOGENSF_N
City Recorder
(SEAL) 1 Notary Public
!11.4, Q.144.°,Mi-tav rB-nt)
My Commission Expires
._'
r