Loading...
HomeMy WebLinkAbout12/09/2024 - Meeting Materials SALT LAKE CITY CORPORATION PERMIT SET Ma,rinttG,ry�en,er m y e = =n I h y rpont Ave 0 Gourmandise A Nteafi Clark Planearium�Q 0e5 ,a05 November 25, 2024 0 ge Ga EU[ah o J H 3 £ 0' Kia05 �- Gallivan Centere 3005 3005 EBroadway F Lake Cen[rel'O 3005 DOWNTOWN 300 © �°.� WMarket S[ o u Sl.Patrick Roman Q u s �' N Hallowetl Grounds Q Catholic Church a ' " Cafe B Gifts ws NLmi—ity Bl.d wWeraNyslvd Salt L• e•City-universiyemd 3 rylvi �t unixa[snq,elve nao s Salt cake _ Publ Lbra =m 500 S e The Lttte America S00 S o e Hotel-Salt Lake Ciry i w J w Washington The.Leonard Q Credit iapman Branch,D y ` h Ameri( m (♦ Wfi005 CHACMOBUENRSCWfi00S + W600S+ Square Park c 0 ihs SODS — SOOS SODS Aspen Fall ekwater Pizza SLC®. i The Little America s wesrzOGs ; 00S Hotel-Salt Lake Ciry _ c we Ezo M The Grand Amenca Hotel® y smithao Salt Lake .0 3 B�a Bea BOOS FAC24088 E600 T—no , aaaB aaaB W 900 S W 900 a W 900 S Harvey Milk Blvd by Gardens /+ N w 3 �� WFSTOR— Libem 451 South State Street Go,9,e Salt Lake City, UIT 84111 Mm�•®'� °�" °°°"�- "'m` VICINITY MAP NOT FOR SITE ORIENTATION MAP OWNER CITY OFFICIALS INDEX CONSTRUCTION No. Name DEPARTMENT OF MAYOR ERINMENDENHALL No. Name A104 2017 ICC A117.1 Reference CITY COUNCIL DIST.1 VICTORIA PETRO A400 Room 315 Plan PUBLIC SERVICES DIST.2 ALEJANDRO PUY DIST.3 CHRIS WHARTON General A401 Enlarged Floor Plan ENGINEERING DIVISION DIST.4 EVA LOPEZ CHAVEZ G000 Cover Sheet A402 Room 315_Interior Elevations DIST.5 DARIN MANO INTERIM DIRECTOR - GEORGE CHAMORRO DIST.G DAN DUGAN A403 Gate Elevation/Sections N CITIY ENGINEER MARK STEPHENS P.E. DIST.7 SARAH YOUNG Architectural A404 Structural Details 0 N IA103 Level 3 Overall Plan A405 13D View Ln 00 " DESIGNER 349 SOUTH 200 EAST, SUITE 600 N ENGINEERING DIVISION - PLACES SALT LAKE CITY, UTAH 84111 u PHONE: 801-535-6059 � Karilyn Anderson, AIA WWW.SLC.GOV/ENGINEERING PROJECT MANAGER DATE PROJECT ARCHITECT DATE L E GOOO Z 41 .o " CITY ENGINEER DATE CITY ARCHITECT DATE FACILITIES DIRECTOR DATE Cover Sheet a o SECTION 303 SECTION 404 CHANGES IN LEVEL DOORS,DOORWAYS AND GATES-"W. az min 303.1 General. B1° 404.2.6 Door and gate hardware..�na Changes in level in floor surtaces shall complywith Section 303. Handles,pulls,latches,locks and other operable parts on doors and gates shall have a shape that is easy to grasp with one hand and does �. not require tight grasping,pinching or twisting of the wrist to operate.The operational force to retract latches or disengage devices that hold the door or gate in a closed position shall be as follows: 303.2 Vertical. 1.Hardware operation by a forward,pushing or pulling motion:15 pounds(66.7 N)maximum. Changes in level of 1/4 Inch(6.4 mm)maximum In height shall be permitted to be vertical. 2.Hardware operation by a rotational motion:28 inch-pounds(315 INcm)maximum. FIGURE 404.2.2(A)CLEAR WIDTH OF DOORWAYS-HINGED DOOR > INSIGHTS(1) __rn_«w.rra 404.2.6.1 Hardware height. FIGURE 303.2 VERTICAL CHANGE IN LEVEL ' JL Operable parts of such hardware shall be 34 inches(865 mm)minimum and 48 inches(1220 mm)maximum above the floor.Where sliding -�; v I 4 doors are in the fully open position,operating hardware shall be exposed and usable from both sides. 303.3 Beveled. 404.2.7 Closing speed. �{---- Changes in level greater than 1/4 inch(6.4 mm)in height and not more than 1/z inch(13 mm)maximum in height shall be beveled with a slope not steeper than 1:2. Door and gate closing speed shall comply with 404.2.7. FIGURE 404.2.3.2(C) 1y� MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS FRONTAPPROACH-PUSH SIDE-EXISTING lri BUILDINGS FOOTNOTES 404.2.7.1 Door and gate closers. Door and gate closers shall be adjusted so that from an open position of 90 degrees,the time required to move the door or gate to an open (A) position of 12 degrees shall be 5 seconds minimum. 404.2.7.2 Spring hinges. AI Door and gate spring hinges shall be adjusted so that from an open position of 70 degrees,the door or gate shall move to the closed position FIGURE 303.3 BEVELED CHANGES IN LEVEL FIGURE 404.2.3.5(D)RECESSED DOORS AND GATES-EXISTING BUILDINGS PULL SIDE in 1.5 seconds minimum. 404.2.8 Door and gate opening force.walrm Fire doors and doors or gates required to be equipped with panic hardware,break away features or other factors requiring higher opening force for safety reasons shall have the minimum opening force allowable in scoping provisions adopted by the appropriate administrative V authority.For other doors or gates,the force for pushing or pulling open doors or gates shall be as follows: F- 1.Interior hinged door:5.0 pounds(22.2 N)maximum. 2.Sliding or folding door:5.0 pounds(22.2 N)maximum. Exception:The force required to retract latch bolls or disengage other devices that hold the door or gate in a closed position shall not apply to panic hardware,delayed egress devices or fire rated hardware. FIGURE 404.2.3.5(E)RECESSED DOORS AND GATES-EXISTING BUILDINGS PUSH SIDE INSIGHTS(1) 404.2.9 Door and gate surface. Door and gate surfaces within 10 inches(255 mm)of the floor,measured vertically,shall be smooth surfaces on the push side extending the full width of the door or gate.Door and gate hardware or any other obstruction or protrusion shall not be mounted in nor extend into the area within 10 inches(255 mm)of the floor.Parts creating horizontal or vertical joints in such surfaces shall be within 1/t6 inch(1.6 mm)of the same plane as the other.Cavities created by added kick plates shall be capped. Exceptions: 1.Sliding doors shall not be required to comply with this section. 2.Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at no less than 60 degrees from the horizontal shall not be required to comply with the 1Nnch(255 mm)bottom rail height requirement. 3.Doors and gates that do not extend to within 10 inches(255 Tim)of the floor shall not be required to comply with this section. 4.The installation of kick plates on existing doors and gates without a smooth surface within 10 inches(255mm)of the floor shall be permitted.The kick plates shall extend to 10 inches(255 man)above the floor and no more than 1 inch(25 man)from the sides and bottom of the door.Cavities created by such kickplates shall be capped. 404.2.10 Vision liter. doors,gates and sidelites adjacent to doors or gates containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one panel on either the door,gate or an adjacent sidelite 43 inches(1090 Turn)maximum above the floor. Exception:Vision Iites with the lowest part more than 66 inches(1675 mm)above the floor shall not be required to comply with this section. 404.3 Automatic and power-assisted doors and gates.�as,4ars NOT F O R 2017 I CC Al 17.1 Accessible and Usable Automatic doors and gates shall comply with Section 404.3.Full powered automatic doors and gates shall comply with ANSI/BHMA At 56.10 Buildings and Facilities sled in Section 106.2.7.Power-assist doors and gates and lowenergy automatic doors and gates shall comply with ANSI/BHMA At 6.19 CONSTRUCTION listed in Section 106.2.6. U 1/8" = 1'-On No. Description Date 2017 ICC A117.1 Reference Karilyn Anderson,AIA COUNCIL CHAMBERS GATE 9 = SALT LAKE CITY CORPORATION Project number FAC24088 N =_ ENGINEERING DIVISION Date 11/25/2024 Al 04 N 451 South State Street Drawn by KA Salt Lake City,UT 84111 Checked by KA Scale 1/8"=1'-0" N Meeting Balcony Office 324 306C 344 Executive Director Office 0❑ 329 327 Office Office 347 349 Break Room Meeting Room 343 323, Lk Open Office Display Area Break Room Open Office O�OM�pp 325 O CITY COUNCIL WORKR P L_w 0 Kitchen 302 342 Open Office Open Office 328 � �\�{^cap 26 322 ® 346 �a e :DN O o Elev. ❑ ❑ Elev. 340 LE 341 Foyer Central Corridor Balco Balcony CITY COUNCIL 307 F30-01 Corridor 306E 04B 304 305 OFFICE OF THE MAYOR 306 Stairs n Stairs up 348 350 Q lul Stairs 338A MIMI === ===M==== Hal Open Office mrin® ®=®m= ®=®==Immm Landing 332 T R Meeting 318 =___ _____ _______= Wome 0 301 Conference Open Office 3386 338 =___ ____® _______= 311 335 336 COUNCIL CHAMBER Men Powder Room 315 331 338C 312 31 Storag Office Conference 333 Office Office 318 317 337 339 Meeting Room Vestibule 314 334 1 - - - — - - - - — A400 A B n LEVEL 3 FLOOR PLAN NOT FOR 3/64" = 1'-0" CONSTRUCTION ° No. Description Date Level 3 Overall Plan Karilyn Anderson,AIA SALT LAKE CITY COUNCIL CHAMBERS GATE co 9 = co CORPORATION Project number FAC24088 ENGINEERING DIVISION Date 11/25/2024 Al 03 r" =, y 451 South State Street Drawn by KA o Salt Lake City, UT 84111 i i iChecked by KA Scale 3164"=1'-0" N Foyer 307 GENERAL NOTES ,0 59'-7° 1.Contractor to verify existing conditions. 2. Re-route any existing wiring on the underside of carpet that interferes with gate installation. _F 5 7 4 7 3. All new wood paneling must match existing:depth, 1'-0" stairs UPI height,proportions,wood specie and stain. 348 4. Contractor to provide mock-up,specifications and ®® ® ® submittals for approval before final fabrication. LA Ll V 5. ADA clearances are shown as the best attempt to comply to current codes in a Existing Historical Building. Open Office ® ® UULALJU ® ®LAUUULAU 415F Will be up pl Code official provide exceptions for items Press not in completely compliance. 318 S.Contractor/Owner to obtain approval from SLC Building LO Services and the Salt Lake City and County Building Conservancy and Use Committee,before starting 1/ Fabrication. ` r Contractor must comply with Door and Gate hardware requirements as described on 2017 ICC A117.1 Accessible and Usable Building and Facilities and 2021 International ®®® ® ® =4 It=D=I=F=®C=D= Building Code. LEa 8.Bullet proof material to be selected by owner. COUNCIL CHAMBER 7F Broadcast 415E � � C 0'-6" F — Kitchenette 312 3'-0" New gote Conference 317 Alcove 3 315D A404 1 Meeting Room A401 31a A B U P�$N -1COUNCIL CHAMBER- ROOM 315 NOT FOR CONSTRUCTION No. Description Date < Room 315 Plan Karilyn Anderson,AIA SALT LAKE CITY COUNCIL CHAMBERS GATE 9 = CORPORATION Project number FAC24088 � ENGINEERING DIVISION Date 11/25/2024 A4 0 0 C14 451 South State Street Drawn by KA Salt Lake City,UT 84111 Checked by KA Scale As indicated N GENERALNOTES Conference Open Office 1.Contractor to verify existing conditions. 317 8 t t interferes any existing wiring on the underside of carpet 318 that interferes with gate installation. 334 S F 3. All new wood paneling must match existing:depth, 768 S F height,proportions,wood specie and stain. 4. Contractor to provide mock-up,specifications and submittals for approval before final fabrication. 5.ADA clearances are shown as the best attempt to comply to current codes in a Existing Historical Building. Will be up to Code Official to provide exceptions for items not in completely compliance. 6.Contractor/Owner to obtain approval from SLC Building 5'-0" Services and the Salt Lake City and County Building Conservancy and Use Committee,before starting Fabrication. q - _ - — Partial North 7. Contractor must comply with Door and Gate hardware requirements as described on 20171CC A117.1 Accessible F X317 X318 Elevation—Room and Usable Building and Facilities and 2021 International 3 315 Building Code. U c 8.Bullet proof material to be selected by owner. V E2 315E co v 0'-0" 1 A403 DA TURNING NEW N o SPACE DOOGATTE—�1 DADA �' 2 Dias North 0 o Elevation clearance. N B — — (D TYp. — v �, o w I � L 4 -0 J 'rLt v 5'-1 1/2" U 3'-07/16" Aprox.- COUNCIL ca CHAMBER � 315 Existing Post 1778 SF Existing pony Wall 0'-6" � Enlarged Floor Plan - Room 315 NOT FOR CONSTRUCTION No. Description Date < Enlarged Floor Plan Karilyn Anderson,AIA SALT LAKE CITY COUNCIL CHAMBERS GATE 9 = CORPORATION Project number FAC24088 � ENGINEERING DIVISION Date 11/25/2024 A4 0 1 N 451 South State Street Drawn by KA Salt Lake City,UT 84111 Checked by KA Scale As indicated N Existing 1 1 GENERALNOTES Door 1.Contractor to verify existing conditions. 2. Re-route any existing wiring on the underside of carpet l0 that interferes with gate installation. -p 3. All new wood paneling must match existing:depth, Existing wall 0 OO height,proportions,wood specie and stain. paneling C 4. Contractor to provide mock-up,specifications and submittals for approval before final fabrication. i 5. ADA clearances are shown as the best attempt to i C to comply to current codes in a Existing Historical Building. i (1) 'X Existing Will be up to Code Official to provide exceptions for items ® ® Existing Door Existing Dias U (D 7'-61/2" mechanical not in completely compliance. 6.Contractor/Owner to obtain approval from SLC Building t FIELD VERIFY casing Services and the Salt Lake City and County Building L Conservancy and Use Committee,before starting Fabrication. 7. Contractor must comply with Door and Gate hardware 0 requirements as described on 20171CC A117.1 Accessible and Usable Building and Facilities and 2021 International M a Building Code. a) LEVEL 3 LEVEL 3 Sim 33' - 7 1/2" `-1 33 - 7 1/2" '',1 8.Bullet proof material to be selected by owner. New Gate wall 2 A403 `O , JI Partial North Elevation Room 315 n Dias North Elevation 1/4" — 1'-011 L _ 1_ 1/41' — 111 0 A TB Existing Dias I I CD 1 A403 0 � 0 � �� 000000 � 000 00000 � 0000 � 0 0 � 0 � i CV _ LEVEL 3 33' --7 1/2" n Dias Front Elevation (East) w t�r r U 1/4" = 1'-0" CONSTRUCTION No. Description Date < Room 315 Interior Elevations 00 Karilyn Anderson,AIA SALT LAKE CITY COUNCIL CHAMBERS GATE — 00 9 = CORPORATION Project number FAC24088 CN ENGINEERING DIVISION Date 11/25/2024 A4 0 2 N 451 South State Street Drawn by KA Salt Lake City,LIT 84111 Checked by KA Scale 1/4"=1'-0" N GENERAL NOTES 1.Contractor to verify existing conditions. 2. Re-route any existing wiring on the underside of carpet that interferes with gate installation. B A 3.All new wood paneling must match existing:depth, height,proportions,wood specie and stain. 4. Contractor to provide mock-up,specifications and submittals for approval before final fabrication. 5. ADA clearances are shown as the best attempt to comply to current codes in a Existing Historical Building. Existing Will be up to Code Official to provide exceptions for items Wall cap not in completely compliance. I I 6.Contractor/Owner to obtain approval from SLC Building Services and the Salt Lake City and County Building Conservancy and Use Committee,before starting Fabrication. Paneling 7. Contractor must comply with Door and Gate hardware spacing and requirements as described on 20171CC A117.1 Accessible and Usable Building and Facilities and 2021 International depth must Wall paneling Building Code. match existing wainscot beyond 6.Bullet proof material to be selected by owner. 2'-10 1/2" do CLEAR OPENING I I I I w Steel > > Post. o o See o a <> °' tructural ih I I / III _LEVEL 3 _ LEVE1/2"L 3 3' -7 1/2" 33' - 7 2 iv A404 n Gate Elevation Gate Section NOT FOR CONSTRUCTION No. Description Date < Gate Elevation / Sections SALT LAKE CITY Karilyn Anderson,AIA COUNCIL CHAMBERS GATE-9 = � CORPORATION Project number FAC24088 ENGINEERING DIVISION Date 11/25/2024 A403 N 451 South State Street Drawn by KA Salt Lake City,LIT 84111 i i iChecked by KA Scale As indicated N ADA Clearances. GENERAL NOTES Typ1.Contractor to verify existing conditions. NOT F O R 2. Re-route any existing wiring on the underside of carpet I that interferes with gate installation. ` CONSTRUCTION J (2) 3. All new wood paneling must match existing:depth, Steel height,proportions,wood specie and stain. Base 4. Contractor to provide mock-up,specifications and �`• Plate. submittals for approval before final fabrication. -'_•4�•` - See 5. ADA clearances are shown as the best attempt to `s'• `• comply to current codes in a Existing Historical Building. ,'�`• .' Structural Will be up to Code Official to provide exceptions for items _'q'�;,=, , O not in completely compliance. ``s I 6.Contractor/Owner to obtain approval from SLC Building Services and the Salt Lake City and County Building Conservancy and Use Committee,before starting ' • '' j Fabrication. `.�� ►`••`. I 7. Contractor must comply with Door and Gate hardware Y--4�� HSS 3x1-1/2x114 POST requirements as described on 2017 ICC A117.1 Accessible `, (S-6'MAX HEIGHT) Sim Existing Posts and Usable Building and Facilities and 2021 International i 1 2'-$1/8" Building Code. _'q'• - I A602 _Door Clearance ^ 8.Bullet proof material to be selected by owner „'s i 5'x8'x3/8'THICK STEEL BASE I � PLATE WITH(6)3/8"0 x 5" (2) `, •` LONG SIMPSON THD375000S 1 F Sim 4% , POST INSTALLED SCREW 11 15/16" 2 Steel post. See ; ANCHORS 1/2" Beveled x A602 Structural Detail wood base 2" 5" 2" ' 3" 0'-6" FACE OF cover- ally HSS �*;::• FLA sides 8 Steel base plate. ::_4'�t=, 3/16 /WEB AT TUBES ILI cos ens. ADA TURNING N 3" See Structural Structural SPACE co detail. _.q.: - �• 1/2" wood trim 317 7 LEVEL 3 OL EQ 9 '4 ' EQ •M Existing carpet `` ,.:• ,..•, X. •`% ,, o Existing Apply sealant all 4• ;' EQ Q concrete slab ,. sides POST AND 3'-2" ANCHOR LAYOUT ON BASE PLATE n Steel Base Detail 1 NEW STEEL POST TO EXISTING CONCRETE ANCHORAGE U3" = 1'-01, A B sIc-01 NO SCALE _ 515 E 100 5,Unit 171J0 SLC City County Building Salt take City,UT 841G2 Council Chamber Gate SK-Ol REAVELEY 801�� �om Detail Sheet n PLAN - STRUCTURAL LAYOUT Engineers io i zoza 11-011 No. Description Date � Structural Details LO Karilyn Anderson,AIA COUNCIL CHAMBERS GATE L.O. 9`= SALT LAKE CITY CN CORPORATION Project number FAC24088 -'_ ENGINEERINGOIVISION Date 11/25/2024 A404 N 451 South State Street Drawn by KA 0 Salt Lake City, UT 84111 to Checked by KA Scale As indicated N GENERALNOTES 1.Contractor to verify existing conditions. 2. Re-route any existing wiring on the underside of carpet that interferes with gate installation. 3. All new wood paneling must match existing:depth, height,proportions,wood specie and stain. 4. Contractor to provide mock-up,specifications and submittals for approval before final fabrication. 5. ADA clearances are shown as the best attempt to comply to current codes in a Existing Historical Building. Will be up to Code Official to provide exceptions for items not in completely compliance. 6.Contractor/Owner to obtain approval from SLC Building Services and the Salt Lake City and County Building Conservancy and Use Committee,before starting Fabrication. 7. Contractor must comply with Door and Gate hardware C \ requirements as described on 2017 ICC A117.1 Accessible \ and Usable Building and Facilities and 2021 International - Building Code. \ 8.Bullet proof material to be selected by owner. 'A To Match Existin Wood Panelin 3D View - New Gate Council Chambers NOT FOR #315 CONSTRUCTION _ No. Description Date Q 4' Karilyn Anderson,AIA 3 D View N 9`- SALT LAKE CITY COUNCIL CHAMBERS GATE N CORPORATION Project number FAC24088 ENGINEERING DIVISION Date 11/25/2024 A4 0 5 N =, 451 South State Street Drawn by KA o T,,, Salt Lake City, UT 84111 Checked by KA Scale 1/4"=V-0" N Door Schedule GENERAL NOTES Room Frame Frame 1.Contractor to verify existing conditions. Room Number Mark Description Height WidthF Finish Type Finish Hardware Comments 2. Re-route any existing wiring on the underside of carpet that interferes with gate installation. 3. All new wood paneling must match existing:depth, COUNCIL CHAMBER 315 315F GATE 7'-0" 2'- 10 1/2" MATCH HM Painted GATE PASSAGE LATCH MORTISE height,proportions,wood specie and stain. EXISTING 4. Contractor to provide mock-up,specifications and submittals for approval before final fabrication. 5. ADA clearances are shown as the best attempt to comply to current codes in a Existing Historical Building. Designs and flnlshes Will be up to Code Official to provide exceptions for items Salr Lake County not in completely compliance. 6.Contractor/Owner to obtain approval from SLC Building The Standard Collection Abbreviation Name Services and the Salt Lake City and County Building The Standard Collection levels can be paired with wit devicesand locks IVEI H.B.Ives Conservancy and Use Committee,before starting SCH from our tooted Schrager and Von Duprin brands And,they are built tothe same Schlage Lock company Fabrication. exacting standards.Our Standard Collection levers offer a more traditional style 7. Contractor must comply with Door and Gate hardware that is appropriate for use in a number of commercial applications. requirements as described on 2017 ICC A117.1 Accessible HARDWARE GROUP NO.GATE and Usable Building and Facilities and 2021 International For use on Door A(s): Building Code. 315E 32613 Each b have: 8.Bullet proof material to be selected by owner. Ol T 02 T 03 7��.�� 2 EA SPRING HINGE 3SP14 5 X 4.5 0 633 NE `i Zt EA PASSAGE SET SR65 03A 626 606 0 626 SCH w 2 EA SILENCER SR65 0 GRY rVE Peseegele<cM1 aatM1iM1earoom ncelo lecF note lock ClaureamlecN m r r amlock N Born iacersalways cnlacF PrlvarylocN -ounmiocFNw. um/wsnLutronlecMiv: iemioae am si elere.5nvev mnmcFw.a cunoniocNsenske nakeabyxee� renter[ry Frymiy� a�� .vn va witn evroo,rumlcelrrslaiml., smanwiN eeineegrrs. ,mmcanrteg�. ems' mvnmie,e erg ess. m e W Fevare bytur n e Mortise Locks Mortise locks require a pocket in the edge of a door into which the lack 4 rul 4 case is fitted.Though more costly than cylindrical locks.this type of Cylinder Formats lock offers greater durability and ® strength.A mortise lock is the strongest,most adaptable lock and is designed to handle high traffic, — i high abuse applications. ® m Project:KFSmall Projects 21121.20 Nepim:X-20743 NOT F O R Print Date:0311U2024 7 14.S.Kw.LSves CONSTRUCTION No. Description Date Door Schedule and Specifications 4, V Karilyn Anderson,AIA COUNCIL CHAMBERS GATE oSALT LAKE CITY NCORPORATProject number FAC24088 ENGINEERING DIVISION Date 11/25/2024A601 N451 South State Street Drawn by KA Salt Lake City,UT 84111 Checked by KA Scale 1/4"=1'-0" N NOT FOR GENERAL NOTES 1.Contractor to verify existing conditions. CONSTRUCTION 2. Re-route any existing wiring on the underside of carpet that interferes with gate installation. 3.All new wood paneling must match existing:depth, 1/2" wood molding height,proportions,wood specie and stain. beyond 4. Contractor to provide mock-up,specifications and submittals for approval before final fabrication. 5. ADA clearances are shown as the best attempt to 1/2" Wood comply to current codes in a Existing Historical Building. Bullet Proof Film Will be up to Code Official to provide exceptions for items molding beyond not in completely compliance. 6.Contractor/Owner to obtain approval from SLC Building Bullet resistant Bullet resistant Services and the Salt Lake City and County Building 5/8" Bullet let Conservancy and Use Committee,before starting 1/2" armor, UL Level 8. armor, UL Level Fabrication. Gap8. Painted to Resistant Film Painted to match 7. Contractor must comply with Door and Gate hardware wood. t match wood. 5„ requirements as described on 2017 ICC At 17.1 Accessible yp and Usable Building and Facilities and 2021 International 5" Typ Building Code. — — — 8.Bullet proof material to be selected by owner. ——— Bullet Resistant Bullet Resistant Oak veneered wood Oak veneered 1/8" wood door to match wood door to match veneer over 13/16" 2" existing finishes existing finishes 2 1/2" Plywood ol q'i -Q -Is.,= m *%% N N co to Lfl to N m Existing Wood Post N Ln- �_ — — — LO 1/8" Oak Veneer Post Centerline to match existing 1/8" Oak Veneer M M to match existing `° 1/2" Oak Veneer 1/2" Oak Veneer paneling to paneling to match existing match existing 2„ — 2° M 1/8" wood Steel wood Steel post and Base veneer over post and base Plate. See 3/8" Plywood _ _— _—J-------J plate. Structural. I_------- -4 - - - - - Existing wall wood Paneling See structural. — 2 1/2" metal stud framed wall. 1/2" Plywood Attach at floor. Wood post n Door Jamb Detail - Hinge Side Sheathing n Door Jamb Detail - Latch Side undisturbed 6" = 1'-0" 6" = 1'-0" No. Description Date < Door Details cli Karilyn Anderson,AIA COUNCIL CHAMBERS GATE M SALT LAKE CITY 9 = CORPORATION Project number FAC24088 N ENGINEERING DIVISION Date 11/25/2024 A602 N 451 South State Street Drawn by KA Salt Lake City,UT 84111 Checked by KA Scale As indicated N